CAD Audio Equitek E100Sx Specifications & Setup

CAD Audio · Condenser microphones

Find the E100Sx power requirement, pickup pattern, pad and high-pass settings in the two-page CAD specification sheet. Match the “E100Sx” marking on the front of your microphone before applying these settings.

Front of the CAD E100Sx condenser microphone with its high-pass and pad switches
CAD Equitek E100Sx shown.

Official manufacturer documents

Equitek E100Sx specification sheet

English · 2 pages · Rev00 1221

Page 1 identifies the microphone and its controls. Page 2 gives the electrical specifications, frequency response and polar plot.

PAC setup help

Check the microphone input

The E100Sx requires 48 V phantom power (P48). Use a microphone input that supplies P48. If you have no signal, check the selected input and its phantom-power setting before raising gain.

Power requirements, page 2

Choose the pad for a loud source

Start at 0 dB for a typical voice recording. If a loud instrument overloads the signal path, select the −10 dB pad and set the input gain again. CAD specifies a maximum of 136 dB SPL with the pad engaged.

Pad and maximum SPL, pages 1–2

Compare the high-pass settings

For a recording with low-frequency rumble, try the 100 Hz high-pass filter and compare a short take against the flat setting. The filter slope is 6 dB per octave. Keep the flat setting when you want to retain more of the source’s low end.

High-pass specification and frequency-response plot, page 2