CAD Equitek E100Sx
The large-diaphragm supercardioid condenser covered by the specification sheet above.
View CAD Equitek E100Sx at PACCAD Audio · Condenser microphones
Find the E100Sx power requirement, pickup pattern, pad and high-pass settings in the two-page CAD specification sheet. Match the “E100Sx” marking on the front of your microphone before applying these settings.

English · 2 pages · Rev00 1221
Page 1 identifies the microphone and its controls. Page 2 gives the electrical specifications, frequency response and polar plot.
The E100Sx requires 48 V phantom power (P48). Use a microphone input that supplies P48. If you have no signal, check the selected input and its phantom-power setting before raising gain.
Start at 0 dB for a typical voice recording. If a loud instrument overloads the signal path, select the −10 dB pad and set the input gain again. CAD specifies a maximum of 136 dB SPL with the pad engaged.
For a recording with low-frequency rumble, try the 100 Hz high-pass filter and compare a short take against the flat setting. The filter slope is 6 dB per octave. Keep the flat setting when you want to retain more of the source’s low end.
The large-diaphragm supercardioid condenser covered by the specification sheet above.
View CAD Equitek E100Sx at PAC